APC ADVMAX2 Room Assessment Upgrade for (1) Data Center Room of up to 2000 sqf./200 sqm or 21-100 racks
Smart-UPS On-Line Features & Benefits Serviceability Disconnected battery notification Warns when a battery is not available to provide backup power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. User-replaceable batteries Increases av
Description
Smart-UPS On-Line Features & Benefits Serviceability Disconnected battery notification Warns when a battery is not available to provide backup power.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Audible alarms Provides notification of changing utility power and UPS power conditions Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Manageability SmartSlot Customize UPS capabilities with management cards.
Serial connectivity Provides management of the UPS via a serial port.
Network manageable Most models provide remote power management options of the UPS over the network.
Many do not have NMC embedded.
LED status indicators Quickly understand unit and power status with visual indicators.
InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
Marketing features Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies.
Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Low operating and maintenance costs with proven reliability and intelligent battery management .
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging.
Automatic self tests insure battery reliability and warn customers in advance of battery replacement.
Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Avoids costly power problems by keeping your IT equipment and data protected and available .
Network grade power conditioning protects from damaging surges and disruptive noise.
The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Save time with easy and convenient remote/network accessibility.
Network manageable via serial, USB or Ethernet.
Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Adaptability Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Protection Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs) Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Availability Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime Allows additional run time to be quickly added as needed.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.
1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts For plug & play UPS Critical Power offers you a full range of distributed service packs.
These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without.
Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours.
Battery Plus, Provides replacement batteries to site, next working day replacement or same day 2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times.
While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA.
In particular, the battery set is of prime importance, and must be in good working order.
With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included Silver Level Gold Level Platinum Level Platinum Plus Technical Hotline 24/7 Yes Yes Yes Yes Preventative Maintenance Yes Yes Yes Yes Remote Monitoring 24/7 Yes Yes Yes Yes Firmware Upgrades Yes Yes Yes Yes Emergency Response Yes Yes Yes Yes Labour Yes Yes Yes Yes Parts Yes Yes Yes option Monthly Event/Status Report option option option option Onsite Crash Kit option option option onsite Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Guaranteed Fix time – – – 4 Clock hours 3: 24×7 Remote Monitoring Contracts – Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
Engineer Installation and configuration during normal hours 24×7 flexible status and remote monitoring.
Encrypted communication, allowing safe offsite monitoring Alarms and events emailed and SMS texted automatically Firewall Friendly Cloud based status overview and multiple sites status on one screen Allows First Fix Response to Site 4.
IR Thermal Imaging Surveys – Infrared electrical inspection.
Infrared electrical testing finds hot, dangerous problems quickly.
Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.
Detect system overloads, loose defective components and damaged switchgear.
Infrared electrical testing finds hot, dangerous problems quickly.
Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss.
Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
5.
Switchgear – Contact us for more information.
Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.
Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard.
This is recommended to be carried out yearly.
Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units.
This is recommended to be carried out every 2 years.
Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV).
Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc.
This is recommended to be carried out every 4 years.
Advantage Max Service Contract Option Advantage Max 2.0