BPC Energy

BPC Energy PowerPro ELMod Series 4kVA-24kVA

SKU PowerPro ELMOD

The Power Pro EL Modular Series is an emergency lighting Inverter that can be configured between 4 – 24kVA with incremental steps of 4kVA power. Designed with high fault clearance capability and operation with high inrush light fittings. The adaptability of the ELMOD system provides three modes of o

Description

The Power Pro EL Modular Series is an emergency lighting Inverter that can be configured between 4 – 24kVA with incremental steps of 4kVA power.

Designed with high fault clearance capability and operation with high inrush light fittings.

The adaptability of the ELMOD system provides three modes of operation as standard and the ability to convert from single phase input to three-phase input without modification.

Low MTTR (Mean Time To Repair) is achieved with all electronic components in a modular format and complete front access.

24kVA power cabinet, built up of 4kVA power modules 1/1 and 3/1 configuration display Hot-Swap power modules True sinewave output Output configurable to 3 modes of operation (Changeover / Inverter / Non-Maintained) Deep discharge protection Reverse battery polarity protection Front access for maintenance and repair Battery short circuit protection Multiple communication options RS232, RS485, dry contacts, TCP/IP Adapter for local and remote communication

Specifications

Specifications
MODEL EL MOD/4 EL MOD/8 EL MOD/12 EL MOD/16
EL
MOD/20
EL
MOD/24
Power Rating kVA/kW
4 / 3.6 8 / 7.2 12 / 10.8 16 / 14.4 20 / 18 24 / 16
INPUT
Nominal Voltage
220/230/240
Vac (1Ph+N+PE)
220/230/240
Vac (1Ph+N+PE) or (3Ph+N+PE)
220/230/240
Vac (1Ph+N+PE)
220/230/240
Vac (1Ph+N+PE) or (3Ph+N+PE) Voltage Range
+25%
Frequency Range
50Hz +10%, 60Hz +10%
OUTPUT
Nominal Voltage
220/230/240
Vac AC Voltage Regulation
+1%
Frequency Range
+4% (+0.2% battery supply)
Power Factor
0.9
Crest Factor
3 1
Harmonic Distortion (Linear Load)
<1%
Transfer Time
<0ms
Waveform Sinewave Load Circuits
1
Overload
120% continuous, 150% for 10 mins, 175% for 1 min
Mode Operation
Changeover,
Inverter and Non-Maintained selectable Maintained
/
Non-Maintained Maintained and Non-Maintained
(standard)
BATTERY
Battery
Type
VRLA AGM
Maintenance Free Sealed Lead
Batteries,
Nickel Cadmium or Plante Internal
/
External
1 or 3 hour external
End of Life
to
EN50171
Included Charge Battery to
80% within 12 hours
Included Deep Discharge Protection Included DC Earth Leakage
Optional
LIGHTING CONTROL INTERFACE
External Mains Fail Test Connection Included Non-Maintained Mode
Connection** Optional
FAR
Optional External Phase Fail
Connection**
Optional
24Vdc
Supply for External Contactor Optional KNX
/ DALI /
NODE
Interface Optional Mains Fail Test Button Key switch with
10min / 1hr / 3hr time delay included
Volt Free Contacts
3
GENERAL
Operating Temperature
-5°C to 40°C / <1000m above=”” sea=”” leve=”” –1000m–=””>
Operating Humidity
<93% non-condensing
Acoustic Noise
<55db at=”” 1=”” metre=”” –55db–=””>
Protection
Degree
IP21
Dimensions (mm) WxDxH
510 x 850 x 1340
Weight (kgs) Excluding Batteries
107 114 121 128 135 142 **
Only applicable if Non-Maintained Contactor Option fitted
| MODEL |
EL MOD/4
|
EL MOD/8
|
EL MOD/12
|
EL MOD/16
|
EL MOD/20
|
EL MOD/24
|
Power Rating kVA/kW
| 4 / 3.6 | 8 / 7.2 | 12 / 10.8 | 16 / 14.4 | 20 / 18 | 24 / 16 | INPUT |
Nominal Voltage
| 220/230/240
Vac (1Ph+N+PE)
| 220/230/240
Vac (1Ph+N+PE) or (3Ph+N+PE)
| 220/230/240
Vac (1Ph+N+PE)
| 220/230/240
Vac (1Ph+N+PE) or (3Ph+N+PE)
|
Voltage Range
| +25% |
Frequency Range
| 50Hz +10%, 60Hz +10% | OUTPUT |
Nominal Voltage
| 220/230/240 Vac |
AC Voltage Regulation
| +1% |
Frequency Range
| +4% (+0.2% battery supply) |
Power Factor
| 0.9 |
Crest Factor
| 3:1 |
Harmonic Distortion (Linear Load)
| <1% |
Transfer Time
| <0ms | Waveform | Sinewave |
Load Circuits
| 1 | Overload | 120% continuous, 150% for 10 mins, 175% for 1 min |
Mode Operation
| Changeover,
Inverter and Non-Maintained selectable
| Maintained / Non-Maintained |
Maintained and Non-Maintained (standard)
| BATTERY |
Battery Type
|
VRLA AGM
Maintenance Free Sealed Lead
Batteries,
Nickel Cadmium or Plante
| Internal / External | 1 or 3 hour external |
End of Life to EN50171
| Included |
Charge Battery to
80% within 12 hours | Included |
Deep Discharge Protection
| Included |
DC Earth Leakage
| Optional |
LIGHTING CONTROL INTERFACE
|
External Mains Fail Test Connection
| Included |
Non-Maintained Mode
Connection** | Optional |
FAR
Optional
|
External Phase Fail
Connection** | Optional | 24Vdc
Supply for External Contactor
| Optional | KNX / DALI /
NODE
Interface
| Optional |
Mains Fail Test Button
|
Key switch with
10min / 1hr / 3hr time delay included |
Volt Free Contacts
| 3 | GENERAL |
Operating Temperature
| -5°C to 40°C / <1000m above=”” sea=”” leve=”” –1000m–=””> |
Operating Humidity
| <93% non-condensing |
Acoustic Noise
| <55db at=”” 1=”” metre=”” –55db–=””> |
Protection Degree
| IP21 |
Dimensions (mm) WxDxH
| 510 x 850 x 1340 |
Weight (kgs) Excluding Batteries
| 107 | 114 | 121 | 128 | 135 | 142
Power Factor | 0.9
Crest Factor
| 3 1
Power Factor | 0.9
Crest Factor
| 3 1